Due to a planned intervention the CERN Document Server website will be unavailable on Wednesday, February 19th, at 18:00 CEST for about 30 minutes.

CERN Accelerating science

CALICE Conference Papers

新增:
2020-02-07
06:03
Exploring the structure of hadronic showers and hadronic energy reconstruction with highly granular calorimeters / Kawagoe, Kiyotomo (Kyushu U.) ; Poeschl, Roman (Orsay, LAL) /CALICE
The CALICE Collaboration pioneers past and present developments of highly granular calorimeters. The prototypes provide unprecedented 3D images of hadronic showers with up to 500000 cells. [...]
SISSA, 2019 - 4 p. - Published in : PoS LeptonPhoton2019 (2019) 152 Fulltext: PDF;
In : XXIX International Symposium on Lepton Photon Interactions at High Energies, Toronto, Canada, 5 - 10 Aug 2019, pp.152

詳細記錄 - 相似記錄
2020-02-07
06:03
Toward Realistic Implementations of Large Imaging Calorimeters / Kawagoe, Kiyotomo (Kyushu U.) ; Emberger, Lorenz Konrad (Munich, Max Planck Inst.) /CALICE
The next generation of collider detectors will most likely make full use of Particle Flow algorithms, requiring precision tracking and imaging calorimeters. The latter, with granularity 2 to 3 orders of magnitude above existing devices, have been developed during the last 15 years by the CALICE collaboration and are now approaching maturity. [...]
SISSA, 2019 - 4 p. - Published in : PoS LeptonPhoton2019 (2019) 151 Fulltext: PDF;
In : XXIX International Symposium on Lepton Photon Interactions at High Energies, Toronto, Canada, 5 - 10 Aug 2019, pp.151

詳細記錄 - 相似記錄
2020-01-15
06:01
Construction and Testing of Novel Designs of Resistive Plate Chambers / Bilki, Burak (Iowa U. ; Beykent U.) ; Onel, Yasar (Iowa U.) ; Repond, Jose (Argonne (main)) ; Xia, Lei (Argonne (main)) /CALICE
Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in their construction. [...]
2019 - 4 p. - Published in : 10.1109/NSSMIC.2018.8824388
In : 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2018), Sydney, Australia, 10 - 17 Nov 2018, pp.8824388

詳細記錄 - 相似記錄
2019-11-23
06:25
Reconstruction and study of hadronic showers with highly granular calorimeters / Chadeeva, Marina (LPI, Moscow (main)) /CALICE Collaboration
The physics and technological prototypes of imaging electromagnetic and hadronic calorimeters developed and operated by the CALICE collaboration have provided an unprecedented wealth of highly granular data of hadronic showers for a variety of active sensor elements and different absorber materials. The main goal of the CALICE research and development activities is to validate the performance of high-granular systems and study different reconstruction schemas. [...]
SISSA, 2019 - 4 p. - Published in : PoS ICHEP2018 (2019) 686 Fulltext from publisher: PDF;
In : XXXIX International Conference on High Energy Physics, Seoul, Korea, 4 - 11 Jul 2018, pp.686

詳細記錄 - 相似記錄
2019-05-28
06:57
Pyrame 3, an online framework for Calice SiW-Ecal / Magniette, F (Ecole Polytechnique) ; Irles, A (Orsay, LAL) /CALICE
Pyrame 3 is the new version of the Pyrame framework [1], with emphasize on the online data treatment and the complex tasks scripting. A new mechanism has been implemented to allow any module to treat and publish data in real time. [...]
2018 - 9 p. - Published in : JINST 13 (2018) C03009
In : Calorimetry for High Energy Frontier, Lyon, France, 2 - 6 Oct 2017, pp.C03009

詳細記錄 - 相似記錄
2019-04-26
04:22
Recent results of the technological prototypes of the CALICE highly granular calorimeters / Pöschl, Roman (Orsay, LAL)
The CALICE Collaboration is conducting R\&D for highly granular calorimeters with an emphasis on detectors for Linear Colliders. [...]
arXiv:1904.02825.
- 2019. - 5 p.
Fulltext

詳細記錄 - 相似記錄
2019-02-22
05:07
Performance of alternative scintillator tile geometry for AHCAL / Tsuji, Naoki (Tokyo U.)
The CALICE Analogue Hadron CALorimeter (AHCAL) at the International Linear Collider (ILC) is a high-granularity hadron calorimeter based on scintillator tiles readout by MPPCs. [...]
arXiv:1902.05266.
- 2019. - 3 p.
Fulltext

詳細記錄 - 相似記錄
2019-02-13
06:57
Tests of Scintillator Tiles for the Technological Prototype of Highly Granular Hadron Calorimeter / Chadeeva, M (Moscow Phys. Eng. Inst. ; Lebedev Inst.) ; Korpachev, S (Lebedev Inst. ; Moscow Phys. Eng. Inst.) ; Rusinov, V (Moscow Phys. Eng. Inst. ; Moscow, ITEP) ; Tarkovskii, E (Moscow Phys. Eng. Inst. ; Moscow, ITEP)
A new technological prototype of the highly granular hadron calorimeter for future collider experiments is being developed by the CALICE collaboration. The proposed baseline design of active elements considers scintillator tiles with a silicon photomultiplier readout. [...]
2018 - 9 p. - Published in : KnE Energ. Phys. 3 (2018) 363-371 Fulltext: PDF;
In : The 3rd International Conference on Particle Physics and Astrophysics, Moscow, Russia, 2 - 5 Oct 2017, pp.363-371

詳細記錄 - 相似記錄
2018-09-07
06:22
Digital HCAL electronics: Status of production / Drake, Gary (Argonne) ; Repond, Jose (Argonne)
This is a status report of the production of the readout electronics for the Digital Hadron Calorimeter (DHCAL) prototype. The prototype will be equipped with Resistive Plate Chambers (RPCs), read out with 1 Oe 1 cm(2) pads. [...]
2011 - 6 p. - Published in : J. Phys. : Conf. Ser.: 293 (2011) , pp. 012014
Fulltext: PDF;
In : 14th International Conference On Calorimetry In High Energy Physics, Beijing, China, 10 - 14 May 2010, pp.012014

詳細記錄 - 相似記錄
2018-09-06
06:02
DQM4HEP : A generic data quality monitoring for high energy physics / Été, R (Lyon, IPN) ; Pingault, A (Gent U.) ; Mirabito, L (Lyon, IPN)
With increasingly sophisticated experiment, online Data Quality Monitoring (DQM) is of a significant importance for the detector and operation efficiency. Most experiments use their own Event Data Model (EDM) for data taking and built a dedicated monitoring system on top of it. [...]
Oct. - 6 p. - Published in : 10.1109/NSSMIC.2016.8069668
In : IEEE Nuclear Science Symposium and Medical Imaging Conference, Strasbourg, France, 29 Oct - 6 Nov 2016, pp.8069668

詳細記錄 - 相似記錄