2019-10-09 06:01 |
A study of the radiation tolerance of poly-crystalline and single-crystalline CVD diamond to 800 MeV and 24 GeV protons
/ Bäni, L (Zurich, ETH) ; Alexopoulos, A (CERN) ; Artuso, M (Syracuse U.) ; Bachmair, F (Zurich, ETH) ; Bartosik, M (CERN) ; Beck, H (Gottingen U.) ; Bellini, V (INFN, Florence) ; Belyaev, V (Moscow Phys. Eng. Inst.) ; Bentele, B (Colorado U.) ; Bes, A (LPSC, Grenoble) et al.
We have measured the radiation tolerance of poly-crystalline and single-crystalline diamonds grown by the chemical vapor deposition (CVD) process by measuring the charge collected before and after irradiation in a 50 m pitch strip detector fabricated on each diamond sample. We irradiated one group of sensors with 800 MeV protons, and a second group of sensors with 24 GeV protons, in steps, to protons cm−2 and protons cm−2 respectively. [...]
2019 - 17 p.
- Published in : J. Phys. D 52 (2019) 465103
Fulltext: PDF;
|
详细记录 - 相似记录
|
2018-10-02 06:14 |
Investigation of charge multiplication in single crystalline CVD diamond particle detectors
/ Muškinja, M (Stefan Inst., Ljubljana) ; Cindro, V (Stefan Inst., Ljubljana) ; Gorišek, A (Stefan Inst., Ljubljana) ; Kagan, H (Ohio State U.) ; Kramberger, G (Stefan Inst., Ljubljana) ; Mandić, I (Stefan Inst., Ljubljana) ; Mikuž, M (Stefan Inst., Ljubljana ; Ljubljana U.) ; Phan, S (Ohio State U.) ; Smith, D S (Ohio State U.) ; Zavrtanik, M (Stefan Inst., Ljubljana)
/RD42
A special metallization pattern was created on a single crystalline diamond detector aimed at creating high enough electric field for impact ionization in the detector material. Electric field line focusing through electrode design and very high bias voltages were used to obtain high electric fields. [...]
2016 - 8 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 841 (2017) 162-169
|
详细记录 - 相似记录
|
2018-08-11 07:06 |
Performance of a diamond - tungsten sampling calorimeter
/ Tesarek, R J (Rutgers U., Piscataway) ; Gilman, Ronald A (Rutgers U., Piscataway) ; Kumbartzki, G (Rutgers U., Piscataway) ; Lee, M H (Rutgers U., Piscataway) ; Rutt, P (Rutgers U., Piscataway) ; Sannes, F (Rutgers U., Piscataway) ; Schnetzer, S (Rutgers U., Piscataway) ; Somalwar, S V (Rutgers U., Piscataway) ; Stone, R (Rutgers U., Piscataway) ; Thomson, G B (Rutgers U., Piscataway) et al.
We report here the first measurements of a diamond-tungsten sampling calorimeter. The calorimeter consisted of twenty layers of diamond with one radiation length of tungsten per layer. [...]
RU-94-03; OHSTPY-HEP-E-94-023.-
1994 - 10 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 349 (1994) 96-105
Fulltext: PDF;
|
详细记录 - 相似记录
|
2013-10-11 04:19 |
详细记录 - 相似记录
|
2007-06-06 04:44 |
详细记录 - 相似记录
|
2005-02-01 03:54 |
Investigation of chemical vapour deposition diamond detectors by X- ray micro-beam induced current and X-ray micro-beam induced luminescence techniques
/ Olivero, P ; Manfredotti, C ; Vittone, E ; Fizzotti, F ; Paolini, C ; Lo Giudice, A ; Barrett, R ; Tucoulou, R
Tracking detectors have become an important ingredient in high-energy physics experiments. In order to survive the harsh detection environment of the Large Hadron Collider (LHC), trackers need to have special properties. [...]
2004
- Published in : Spectrochimica Acta, B 59 (2004) 1565-1573
|
详细记录 - 相似记录
|
2004-12-07 06:50 |
The development of diamond tracking detectors for the LHC
/ Adam, W ; Berdermann, E ; Bergonzo, P ; de Boer, Wim ; Bogani, F ; Borchi, E ; Brambilla, A ; Bruzzi, M ; Colledani, C ; Conway, J et al.
Chemical vapor deposition diamond has been discussed extensively as an alternate sensor material for use very close to the interaction region of the LHC where extreme radiation conditions exist. During the last few years diamond devices have been manufactured and tested with LHC electronics with the goal of creating a detector usable by all LHC experiment. [...]
2003
- Published in : Nucl. Instrum. Methods Phys. Res., A 514 (2003) 79-86
|
详细记录 - 相似记录
|
2000-08-31 00:00 |
详细记录 - 相似记录
|
2000-07-31 00:00 |
详细记录 - 相似记录
|
2000-03-22 00:00 |
Micro-strip sensors based on CVD Diamond
/ Adam, W ; Berdermann, E ; Bergonzo, P ; Bertuccio, G ; Bogani, F ; Borchi, E ; Brambilla, A ; Bruzzi, Mara (INFN and Universita', Firenze, Italy) ; Colledani, C ; Conway, J et al.
In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation..
CERN-EP-2000-041.-
Geneva : CERN, 2000 - 10 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 453 (2000) 141-148
Fulltext: PDF;
- CERN library copies
|