CERN Accelerating science

CMS Detector Performance Summaries

Najnovije dodano:
2019-11-12
15:19
ECAL 2018 refined calibration and Preshower Run 2 performance plots /CMS Collaboration
Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. Following the excellent performance achieved in Run I at center-of-mass energies of 7 and 8 TeV, the CMS electromagnetic calorimeter (ECAL) is operating at the LHC with proton-proton collisions at 13 TeV center-of-mass energy. [...]
CMS-DP-2019-038; CERN-CMS-DP-2019-038.- Geneva : CERN, 2019 - 25 p. Fulltext: PDF;

Detaljnije - Slični zapisi
2019-11-12
15:19
Emittance scans comparison with LHC wire scanner /CMS Collaboration
High-luminosity production at the LHC is closely linked to the size of the transverse beam emittance. However emittance measurement is challenging. [...]
CMS-DP-2019-039; CERN-CMS-DP-2019-039.- Geneva : CERN, 2019 - 16 p. Fulltext: PDF;

Detaljnije - Slični zapisi
2019-11-12
15:19
Performance of a standalone simulation and potential improvements of the ECAL trigger primitive algorithms using LHC Run 2 data /CMS Collaboration
This note presents the performance of the ECAL trigger primitive algorithms in LHC Run 2, focusing on the reconstruction of signal amplitudes in the ECAL endcaps. Results are presented on the performance of the standalone simulation and on potential improvements in these algorithms that are being considered for LHC Run 3..
CMS-DP-2019-040; CERN-CMS-DP-2019-040.- Geneva : CERN, 2019 - 15 p. Fulltext: PDF;

Detaljnije - Slični zapisi
2019-10-30
14:04
The MIP Timing Detector /CMS Collaboration
These slides contain approved figures on the MIP Timing Detector design and performance..
CMS-DP-2019-037; CERN-CMS-DP-2019-037.- Geneva : CERN, 2019 - 51 p. Fulltext: PDF;

Detaljnije - Slični zapisi
2019-10-30
14:03
Efficiency of the Pixel sensors used in the Precision Proton Spectrometer: radiation damage /CMS Collaboration
The Precision Proton Spectrometer (PPS) is a forward-proton spectrometer using near-beam detectors (inside Roman Pots, RPs) located symmetrically on both sides of IP5 at a distance of about 220 m. In 2017 (2018) two (four) RPs were equipped with with 3D pixel sensors, which by the end of Run-II collected $\sim$100/fb. This note describes the method used to evaluate the effect of the non-uniform irradiation on the readout chip, and its consequences on the efficiency..
CMS-DP-2019-036; CERN-CMS-DP-2019-036.- Geneva : CERN, 2019 - 17 p. Fulltext: PDF;

Detaljnije - Slični zapisi
2019-10-24
17:17
Time resolution of the diamond sensors used in the Precision Proton Spectrometer /CMS Collaboration
The Precision Proton Spectrometer (PPS) is a forward-proton spectrometer using near-beam detectors (inside Roman Pots, RPs) located symmetrically on both sides of IP5 at a distance of about 220 m. In addition to the tracking system, timing detectors were installed in 2017 to measure the Time-Of-Flight (TOF) of the protons produced in central exclusive interactions. [...]
CMS-DP-2019-034; CERN-CMS-DP-2019-034.- Geneva : CERN, 2019 - 15 p. Fulltext: PDF;

Detaljnije - Slični zapisi
2019-10-18
15:25
Performance of the DeepTau algorithm for the discrimination of taus against jets, electron, and muons /CMS Collaboration
The performance of the newly developed DeepTau algorithm for the discrimination of taus against jets, electrons, and muons is summarized. The algorithm exploits recent deep neural network multi-classification methods. [...]
CMS-DP-2019-033; CERN-CMS-DP-2019-033.- Geneva : CERN, 2019 - 9 p. Fulltext: PDF;

Detaljnije - Slični zapisi
2019-10-15
10:02
Pixel Luminosity Telescope per-channel data with and without reweighting derived from emittance scans to account for detector efficiency and linearity /CMS Collaboration
We present Pixel Luminosity Telescope (PLT) per-channel luminosity values as a function of time, showing the total (i.e., over all bunches) instantaneous luminosity as measured by the PLT detector with and without reweighting derived from emittance scans to account for detector efficiency and linearity. A part of the fill 6860 is shown..
CMS-DP-2019-032; CERN-CMS-DP-2019-032.- Geneva : CERN, 2019 - 5 p. Fulltext: PDF;

Detaljnije - Slični zapisi
2019-09-27
16:37
CMS ECAL trigger plots /CMS Collaboration
This note presents the performance of the ECAL trigger primitive algorithms in LHC Run 2, focusing on the reconstruction of signal amplitudes in the ECAL barrel and endcaps, and the rejection of anomalous signals in the ECAL barrel photodetectors. Results are also presented on potential improvements in these algorithms that are being considered for LHC Run 3..
CMS-DP-2019-031; CERN-CMS-DP-2019-031.- Geneva : CERN, 2019 - 43 p. Fulltext: PDF;

Detaljnije - Slični zapisi
2019-09-27
16:37
CMS ECAL Laser Monitoring System /CMS Collaboration
The plots show the behavior of the ECAL laser monitoring system in 2018, in particular measurements of the stability of the laser amplitude inside the detector, measured by PiN and PN diodes through optical fibers, and residual energy-scale corrections obtained with electron track-to-momentum ratio in collision events
CMS-DP-2019-030; CERN-CMS-DP-2019-030.- Geneva : CERN, 2019 - 8 p. Fulltext: PDF;

Detaljnije - Slični zapisi